空調系統的減振設計對消聲和減振有哪些措施?
What measures does the vibration reduction design of the air conditioning system have for noise reduction and vibration reduction?
![空調系統的減振設計對消聲和減振有哪些措施?](/uploads/190225/1-1Z2250Z6104I.jpg)
1.在空調系統中,空調機組應最好采用彈簧減震器,按機組功率及安裝位置不同選擇不同的撓度的彈簧減震器,大功率設備可選用40MM撓度的彈簧減震器,較小功率空調主機可使用25MM常規彈簧減震器。同空調主機,風機水泵也應用彈簧減震器做減振處理.并且適情況增加減震基座.除了對風機、水泵等產生振動的設備設置彈性減振支座外,還應在風機與風管之間采用軟管鏈接,風管接頭宜采用人造材料或帆布材料制作。6號以下風機,軟管的合理長度為200mm;8號以上的風機,軟管合理長度為400mm.
1 in the air conditioning system, the air conditioning unit should be the best use of spring shock absorber, according to the unit power and installation position of different choice of different deflection of the spring shock absorber, large power equipment can choose the 40MM deflection of the spring shock absorber, smaller power air conditioning host can use 25MM conventional spring shock absorber.In addition to the vibration of the fan, water pump and other vibration equipment set up elastic vibration damping support, should also be used between the fan and the duct hose link, duct joint should be made of artificial materials or canvas materials.For fans below no.6, the reasonable length of the hose is 200mm;For fans above no.8, the reasonable length of hose is 400mm.
![空調系統的減振設計](/uploads/190225/1-1Z225094319416.jpg)
2.水泵、冷水機組、風機盤管、空調機組等設備與水管之間用軟管連接,不使振動傳遞給管路。軟管有兩類:橡膠軟接管和不銹鋼波紋管。橡膠軟接管隔振減噪的效果很好,缺點是不能耐高溫和高壓,耐腐蝕性也差。在空調與采暖的水系統中多用橡膠接管。不銹鋼波紋管能耐高溫、高壓和耐腐蝕,但價格較貴,一般用于制冷劑管路的隔振。
2. Connect water pumps, chillers, fan coils, air conditioning units and other equipment with water pipes with hoses, so that vibration is not transmitted to the pipes.There are two types of hoses: soft rubber nozzles and stainless steel bellows.Rubber soft noise-isolation effect is very good, the disadvantage is not able to high temperature and high pressure, corrosion resistance is also poor.Rubber nozzles are used in air conditioning and heating water systems.Stainless steel bellows can withstand high temperature, high pressure and corrosion resistance, but the price is more expensive, generally used for refrigerant pipeline isolation.
3.在管路的支吊架、穿墻處使用非燃軟性材料填充做減振處理。振動較大的設備吊裝時,采用吊式彈簧減震器。
3. Use non-combustible soft materials to fill the support and hanger and through the wall of pipelines for vibration reduction.Vibration of the larger equipment when hoisting, the use of hanging spring shock absorber.
4.選用高效、低噪聲水泵、風機,并使水泵、風機在最高效率點附近運行。
4. Choose high efficiency and low noise water pump and fan, and make the water pump and fan run near the highest efficiency point.
5.按噪聲標準控制風管、風口風速,以滿足房間噪聲要求。
5. Control the wind speed of air duct and tuyere according to the noise standard to meet the room noise requirements.
6.空調機房內壁表面貼附吸聲材料及吸聲孔板,機房門采用消聲密閉門,使墻體有吸聲能力,等等
6. Sound absorption material and sound absorption hole plate are attached to the inner wall surface of the air conditioning room. The door of the machine room is closed with muffler, so that the wall has sound absorption ability, etc
![空調系統減震器的組合](/uploads/190225/1-1Z2250941234I.jpg)
6. Sound absorption material and sound absorption hole plate are attached to the inner wall surface of the air conditioning room. The door of the machine room is closed with muffler, so that the wall has sound absorption ability, etc
與空調系統的減振設計對消聲和減振有哪些措施?相關的文章
減震墊內部結構的阻尼系數
減震墊內部結構的阻尼系數 減震墊密封環移位,螺絲未擰緊,漏油,殼體密封性差,柜門有空隙,器件非常容易被灰塵環境污染,或潮濕進入浸蝕。減震墊設置在家具家具木地板或地板…
減震器啟動前的準備及檢查
減震器啟動前的準備及檢查:
1、檢查屏蔽電機和啟動設備的接地裝置是否良好和完整,接線是否正確,接觸是否可靠。
2、對新安裝和長期停用的屏蔽電機,使用前應檢查電機定子繞…
怎樣檢測轎車fox轉向減震器保修規定
怎樣檢測轎車fox轉向減震器保修規定生活中振動的現象是不容忽視也是不可缺少的,所有的物體的振動都會產生聲音,而人們也一直致力于振動的產生,控制和消除的研究,??在橡膠應用于工…
如何改裝合肥阿壩彈簧減震器保質2年能不
如何改裝合肥阿壩彈簧減震器保質2年能不能買?中秋即將來臨,我們無錫市松夏橡膠減震器有限公司先提前祝大家節日快樂吧!不知道大家有什么打算,畢竟中秋是我國的一個團圓節,而…
吊式彈簧減震器ZTA-80螺桿冷水機活塞hs編
吊式彈簧減震器ZTA-80螺桿冷水機活塞hs編碼在吊式彈簧減震器中的往復運動是通過與之間的液壓腔液體傳遞給的。為了維持要的正常運動要求液壓腔封閉空間內液體的體積保持不變。這樣…
阻尼彈簧減振器ZTA-4800空調冷水機的技術
阻尼彈簧減振器ZTA-4800空調冷水機的技術狀況新的媒介平臺的崛起,各種新的營銷手段層出不窮,阻尼彈簧減振器廠企業在講求渠道創新之余對于營銷模式的創新也有著不少的要求,但是…